Breast Aspiration, Multi-Hole Biopsy Needle
with 3 Finger Control 12cc Syringe
Billing Information:
CPT Procedure Code: 88170
Supplies: 99070
|
Milex Codes:
|
|
1 1/2" Needle: 41
3" Needle: 40
|
Sterile/Disposable/One-time use
| |
Latex Free

Sterile/Disposable/One-time use
|
Abbreviated information:
Fine needle aspiration biopsy is a simple, cost-effective, safe office procedure for the evaluation of all palpable breast masses.
Purpose:
Cytologic evaluation of breast nodules and cysts
Differentiation of breast lesions
Indications:
Any lesion of the breast which can be palpated should be aspirated to help:
- Establish a diagnosis
- Assist in determining extent of disease
- Evacuate a cyst
- Distinguish between diffuse suppurative mastitis and carcinoma with associated severe inflammation
- Confirm diagnois of inoperable carcinoma of the breast prior to radiotherapy
Advantages:
- High degree of accuracy
- Less traumatic
- Well tolerated by the patient
- Rapid diagnostic tool
- Beveled needle and side port help ensure adequate sampling of typical breast mass
- Stylet assures ease of insertion into mass or cyst without picking up material from outside of the mass
- Reduces need for hospitalization and saves OR time and expense
- Useful adjunct to diagnosis of malignant disease
- Useful for following patients with chronic cystic mastopathy
- Clear hub of needle enables you to observe removal of specimen
- Especially useful with pregnant patients when mammography is contraindicated
Limitations:
- A benign fine needle aspiration cannot be sole basis for diagnosis of breast pathology. If clinical and/or laboratory evidence suggests a malignancy, additional test procedures are indicated regardless of benign cytologic diagnosis.
- The size or depth of a lesion may be limiting factor without radiographic guidance.
Packed:
- 12 Breast Aspiration Sets per box
- (1) 22 Gauge Multi-Hole Needle and (1) Finger Control 12cc Syringe per set
- Informed Consent Forms enclosed
- Complete instructions enclosed within each box

FIG. 1
22 gage needle
- 22 gauge thin wall needle obtains sample comparable to standard 18 gauge needle with less trauma
- Less likely to cause hematoma
FIG. 2 & 3
Triangular cut beveled end & side port
- Triangular cut retrieves several time sample size as other aspiration needles

FIG. 4
Stylet (Beveled End)
- Avoids picking up tissue from outside the mass
- Helps ensure ease of insertion

FIG. 5
Clear Hub
- Helps avoid "Dry Taps"*
- Suction continued until some material appears in hub
- Suction discontinued before specimen reaches syringe*

*Oertel, Y.C.: Fine Needle Aspiration of the Breast, 1987, p. 18
|