Uterine Explora Model I
with Vacu-Lok Syringe
Billing Information:
CPT Code: Procedure: 58100
Supplies: 99070
Milex Product Codes:
3mm #120
4mm #124
Histology:
Tissue Retrieval
Nylon Curette 7 3/4" long with Randall-type cutting edge and Vacu-Lok Syringe.
|
|
Latex Free

Packed 25 per box*
|
Abbreviated Information:
Nylon curette with sharp Randall-type cutting edge to assure better sampling from all areas of the endometrial cavity. Vacu-Lok syringe allows you to adjust the suction from approximately 15 to 20 inches Hg negative pressure.
|
Uterine Explora Model II
with Vacu-Lok Syringe
Billing Information:
CPT Code: Procedure: 58100
Supplies: 99070
Milex Product Codes:
#130
Histology:
Endometrial Tissue Retrieval
Nylon Curette 7 3/4" long with Dual port design and Vacu-Lok Syringe.
|
|
Latex Free

|
Abbreviated Information:
The dual port design is suitable for patients with low pain threshold or who are very apprehensive. Tissue is obtained via a scraping and peeling action. Vacu-lock syringe allows you to adjust the suction from approximately 15 to 20 Hg negative pressure. (6cc to 12cc)
Purpose:
Obtain clearly differentiated endometrial tissue usually without anesthesia in an office setting. Diagnostic accuracy of histology of the endometrium is far superior to that of cytology.
Indications:
- Detection of endometrial hyperplasia
- Detection of endometrial cancer
- Initial endometrial biopsy prior to prescribing estrogen replacement therapy to ensure endometrial lining is normal
- Periodic monitoring of endometrial tissue in women receiving estrogen replacement therapy
- Endometrial dating
- Examination of glandular epithelium to determine ovulation and endometrial response to hormonal excretion and therapy
- Detection of pathology resulting in infertility
- Endometrial biopsy for postpartum endometritis
- Bacterial culturing
- Monitor patient receiving TAMOXIFEN therapy for breast cancer
- Secondary amenorrhea
Advantages:
- Dual Port design ideal for patient with low pain threshold or extreme anxiety
- Better sampling from all areas
- Flexible nylon curette
- Ease of insertion
- Better sampling from difficult-to-reach cornual areas
- Rounded end and collar ring minimize possibility of perforation
- Added suction from Vacu-Lok Syringe.
Limitations:
- Small lumen curettes are contraindicated in patient with a large cervical os because there is the loss of suction around the curette.
Recommendation:
Cannula-Curette with Handyvak Locking 60cc Syringe or Tis-U-Trap.
- Small lumen curettes are contraindicated in patient with dysfunctional uterine bleeding. Clots can clog curette.
Recommendation:
Cannula-Curette with Handyvak Locking 60cc Syringe or Tis-U-Trap.
Contraindications:
Contraindicated in the presence of any vaginal, cervical, and/or pelvic infection(s). Infections must be treated prior to any endometrial curettage or biopsy.
In general, the same criteria for regular hospital D & C should be
followed for office suction curettage.
General:
Total physician time 5-15 minutes
*Packed:
- Box of 10 or 25 sets
- Curette, Syringe
- Informed Consent Forms enclosed
- Complete instructions enclosed within each box
- Comprehensive information included with each order